Predesign
___
All required deliverables submitted.
___
Consistent with DSC Structural Design Standards.
Schematic Design
___
All required deliverables submitted.
___
Consistent with DSC Structural Design Standards.
___
Correct Building Code used.
___
Correct loads (Live, Snow, Wind Seismic) used.
___
Floor framing system(s) appropriate for the structure.
___
Roof framing system appropriate for the structure.
___
Lateral force system appropriate for the structure.
Design Development (DBB or DB)
___
All required deliverables submitted.
___
Consistent with DSC Structural Design Standards.
___
NPS structural standards followed.
___
Correct Building Code used.
___
Occupancy Category correct.
___
Snow Load correct.
___
Snow Load Importance Factor correct.
___
Roof LL correct.
___
Floor LL's correct.
___
Wind Design parameters correct.
___
Seismic Design Parameters correct.
___
Foundation design consistent w/Geotech Report.
___
Floor framing system(s) appropriate for the structure.
___
Roof framing system appropriate for the structure.
___
Lateral force system appropriate for the structure.
___
Larger members for larger spans.
___
Larger footings at more heavily loaded columns.
___
Structural dimensions match Architectural drawings.
___
Column orientation matches Architectural drawings.
___
Column grid lines match Architectural drawings.
___
Column and bearing wall locations match Architectural drawings.
___
Complete and continuous load path for gravity loads.
___
Complete and continuous load path for lateral loads.
___
Outline specs provided for all required sections.
100% Draft Construction Documents (DBB) or 100% Draft Design-Build Construction Documents (DB)
General
___
All required deliverables submitted.
___
Consistent with DSC Structural Design Standards.
___
Correct Building Code used.
___
Floor framing system(s) appropriate for the structure.
___
Roof framing system appropriate for the structure.
___
Lateral force system appropriate for the structure.
___
Larger members for larger spans.
___
Larger footings at more heavily loaded columns.
___
Structural dimensions match Architectural drawings.
___
Column orientation matches Architectural drawings.
___
Column grid lines match Architectural drawings.
___
Column and bearing wall locations match Architectural drawings.
___
Complete and continuous load path for gravity loads.
___
Complete and continuous load path for lateral loads.
___
Support for mechanical and electrical equipment.
Loads
___
Occupancy Category correct.
___
Snow Load correct.
___
Snow Load Importance Factor correct.
___
Roof LL correct.
___
Floor LL's correct.
___
Floor LL reduction.
___
Wind Design parameters correct.
___
Seismic Design Parameters correct.
___
Flood loads.
___
Special loading conditions (cranes, heavy equipment, etc. (addressed).
___
Requirements for special inspection shown.
Foundation
___
Foundation design consistent with Geotechnical Report.
___
Footing step elevations close.
___
Foundation wall step elevations close.
___
Hold down locations clearly shown.
___
Seismic requirements for pile foundations.
Concrete
___
Minimum concrete cover shown.
___
Tie spacing and arrangement correct.
___
Control joint spacing in slabs-on-grade.
___
Expansion joints - floors, walls, roofs.
___
Two mats of steel provided for walls 10" and thicker.
___
Minimum compression member reinforcing 0.01Ag ≤ As ≤ 0.08Ag.
___
Minimum foundation pedestal reinforcing 0.005Ag ≤ As.
___
Minimum footing thickness 6" above bottom reinforcing on soil.
___
Minimum footing thickness 12" above bottom reinforcing on piles.
___
Retaining wall reinforcing shown in the correct locations.
Masonry
___
Masonry dimensions modular.
___
Control joint locations and spacing for masonry construction.
___
Seismic detailing provided.
Steel
___
Adequate stiffeners provided.
___
Complicated/unusual connections detailed.
___
Reactions/loads provided for connections not detailed.
___
Base plates - 4 anchor bolts minimum.
___
Minimum fillet weld size shown.
___
Special loading conditions for steel bar joists shown.
___
Bar joist connections at columns.
___
Bar joist seat depth correct.
___
Bar joist bridging shown.
___
Bar joist bridging connection to wall or frame.
___
Weld pattern for steel decks shown.
___
Sidelap and endlap fastening.
___
Steel decking continuous over three spans.
Wood
___
Notches and holes.
___
Truss bottom chords braced for compression due to load reversals.
___
Truss profiles provided for prefab trusses.
___
Truss loading requirements shown.
___
Permanent bracing of prefab trusses shown.
___
Cross grain bending and tension avoided.
___
Nailing schedule provided.
___
Diaphragm and shearwall nailing shown.
___
Top plate splice detail shown.
___
Roof diaphragm shear transfer to shearwalls shown.
Specs
___
Contracting Officer vs. Engineer.
___
All required specification sections provided.
___
Shoring and bracing of excavations.
___
Compaction testing frequency.
___
Appropriate cement type.
___
Water-cement ratio 0.45 max.
___
Testing frequency.
___
Mortar and grout specified correctly.
___
Wood treatment - no CCA.
___
Materials conform to structural standards.
Calcs
___
Deflection limits correct.
___
Concrete and masonry wall anchorage.
___
Partition live load included.
___
Folding partitions accounted for.
___
Load combinations used correctly.
___
Roof DL corrected for slope.
___
Unbalanced snow loading.
___
Snow drifting.
___
Minimum wind pressure 10 psf for MWFRS.
___
Minimum wind pressure 10 psf for components & cladding.
___
Enclosed vs. partially enclosed.
___
Wind uplift addressed.
___
R, Ω, and Cd correct.
___
Ponding on flat roofs.
___
Flexural strength reduction.
___
Moment magnification considered for concrete columns.
___
Crack control for reinforced concrete structures.
___
"Rolling" forces considered for purlins.
___
Second order effects considered for steel frames.
___
Load duration factors applied correctly for timber design.
100% Complete Construction Documents (DBB) or 100% Complete Design-Build Construction Documents (DB)
___
All required deliverables submitted.
___
All review comments from 100% Draft Review satisfactorily resolved.